Version 3.1.2
What's new in this release?
- Important bug fixes
- In this release, we've addressed some important issues to improve usability and reliability.
- VidyoReplay 3.1.2 is compatible with VidyoPortal versions 3.3.x and 3.4.x.
- System updates
- For added security and stability, updates for multiple third-party packages and libraries are included as part of this release.
Files
This file... |
Should be applied on top of... |
---|---|
N/A |
N/A |
Important notices
- You must apply VidyoReplay version 3.1.2 on top of VidyoReplay version 3.x. If you have a VidyoReplay version earlier than 3.x, you must first upgrade to 3.x, then incrementally upgrade versions to version 3.1.2. Once you have done so, refer to the Upgrade a VidyoReplay Cluster to 3.1.2 section below. These steps must be completed in order.
- Multiple Super users can be managed only from the Active Controller in a VidyoReplay cluster.
Upgrade a VidyoReplay cluster to 3.1.2
Due to the database changes required for this new feature, the procedure for upgrading an existing Replay cluster is the following:
- Upgrade all recording nodes in the cluster. Note: You cannot log in to recorder nodes until the entire cluster upgrade is completed.
- Log in to each controller and reconfigure them as standalone.
- Log in to each standalone cluster and perform the upgrade.
- Log in to the old active controller and reconfigure it in cluster mode. The machine will reboot. Check the portal to see if the machine is properly registered.
- Once registered, you can log in with the default user (‘super’). The Users tab should be visible. The Settings > Cluster > Component Status page should show the current machine as an active controller with all the recorders present.
- Log in to the old standby controller and reconfigure it in cluster mode. The machine will reboot.
- The active controller page located at Settings > Cluster > Component Status should now show the successful replication and that both controllers are currently online.
- You can now log in via the UI on any machine in the cluster.
Notes:
- We recommend taking a snapshot of the machines using VidyoConsole, or via VMware if using a virtual machine.
- It is mandatory to perform the above procedure step-by-step. Failure to do so may result in unexpected results, including the inability to log in. In such cases, you can revert to a previous snapshot.
- If a recorder node is reconfigured as standalone, the Users database is cleared and the default username/password combination may be used to log in.
- If a controller is reconfigured as standalone, the Users database remains untouched.
Compatibility
VidyoReplay version 3.1.2 is compatible with VidyoPortal versions 3.x and later.
If your organization has an on-premises VidyoPortal (rather than a cloud subscription), refer to the Vidyo compatibility matrix to determine which endpoint versions are compatible with your VidyoReplay release.
Resolved issues
The following table lists the issues we have resolved in VidyoReplay version 3.1.2.
VidyoReplay version 3.1.2 - resolved issues |
|
---|---|
Key |
Summary |
RPLY-780 |
Cross Site Request Forgery (CSRF) issues in the VidyoReplay Admin UI are now fixed. |
RPLY-769 |
A cross-site scripting issue, which allows a user to execute Javascript on the browsers of users accessing VidyoReplay, is now fixed. |
Known issues
VidyoReplay version 3.1.2 - known issues |
|
---|---|
Key |
Summary |
RPLY-1335 |
If using a password-based transport (SCP, FTP, SFTP), Automatic Recording Export fails if the password contains an exclamation mark. |
RPLY-1333 |
When using the Automatic Recording Export feature, metadata is exported. |
RPLY-1323 |
When using the Test Connection script, the TestConnection button returns "Cannot establish connection." In addition, if embedded metadata is set in the web page, it is saved as export.metadata.format=None, but the export.sh script checks for none (without the capital N). |
RPLY-1282 |
Content share is not recorded if the recording profile is set to 1 as the maximum number of participants. |
RPLY-610 |
The clipboard does not display correctly in the VidyoReplay Library and nothing happens upon clicking it. |
RPLY-446 |
During a call, the number of participants on the Call Status page drops to zero when the camera is set to privacy mode. Workaround: Use the Admin portal, Super portal, Control Meeting, or Participant List to view the correct number of participants on the call. |
RPLY-306 |
When a room owner starts a webcast, their name does not display in the Participant List. |