Version 22.1.1

What's new in this release?

  • Fix for "No camera" icon issue
  • This release fixes an issue where the VidyoReplay recording would display a "No camera" icon even when there were still video-enabled participants in the call. This occurred when VidyoReplay received a client resolution that had an odd width or height. In this release, when an odd client resolution is received, VidyoReplay will normalize it.
  • VidyoReplay will also log the error with the "source image normalized to X lines" message so customers are aware when this occurs.

Files

This file...

Is for...

rp-TAG_RP_22_1_1_0.signed.vidyo

VidyoReplay version 21.1.0 or later

Important notices

  • You must apply VidyoReplay version 22.1.1 on top of VidyoReplay version 22.1.0. If you have a VidyoReplay version earlier than 19.1.0, you must first upgrade to 19.1.0, then upgrade to 22.1.0, and then upgrade to version 22.1.1. Once you have done so, refer to the Upgrade a VidyoReplay Cluster to 22.1.1 section below. These steps must be completed in order.
  • IMPORTANT NOTE: In order to support HTML5 playback, when you upgrade to VidyoReplay 22.1.1, your existing recordings undergo an automatic conversion process. It takes approximately 30 seconds to convert an hour-long video. During the conversion process:
  • Recordings that are in the queue to be converted cannot be played back via the web interface.
  • Recordings are available for download.
  • New recordings can be made; however, as the number of recordings in progress increases, the automatic conversion process may slow down.
  • We highly recommends upgrading to VidyoReplay 22.1.1 during a period of expected low usage to allow the conversion process to complete.

Upgrade a VidyoReplay cluster to 22.1.1

To upgrade a VidyoReplay cluster to 22.1.1, you must perform the following steps in order:

  1. Place all Cluster Nodes into Maintenance mode.
  2. Upgrade all the Cluster Nodes.
  3. When the Cluster Node upgrades are completed and back online, upgrade the current Standby Controller.
  4. When the Standby Controller upgrade is complete, upgrade the Active Controller. The previous Standby Controller will now become the 22.1.1 Active Controller.
  5. When the former Active Controller completes its upgrade, it will then become the 22.1.1 Standby Controller.
  6. Note: If you do not perform the above steps in order, there will be cluster instability and/or configuration loss.

Compatibility

VidyoReplay version 22.1.1 is compatible with VidyoPortal versions 20.1.x or later.

If your organization has an on-premises VidyoPortal (rather than a cloud subscription), refer to the Vidyo compatibility matrix to determine which endpoint versions are compatible with your VidyoReplay release.

Resolved issues

The following table lists the issue we've resolved in VidyoReplay version 22.1.1.

VidyoReplay Version 22.1.1 - resolved issue

Key

Summary

RPLY-1534

When VidyoReplay Version 22.1.1 receives a client resolution that has an odd width or height, it will normalize it. It will also log the error with this message: "source image normalized to X lines".

Known issues

There are no new known issues for this release.