Version 24.2.1
What's new in this release?
- Bug fixes
- In this release, we've addressed some issues to improve usability and reliability.
- System updates
- For added security and stability, updates for multiple third-party packages and libraries are included as part of this release.
SSH configuration information
In this version, the SSH configuration has been updated to improve security. Because of these changes, only modern SSH clients that support the configurations below will typically be able to successfully connect.
- Supported host keys: RSA,ED25519
- Key exchange algorithms: diffie-hellman-group-exchange-sha256,diffie-hellman-group18-sha512,diffie-hellman-group16-sha512,curve25519-sha256,sntrup761x25519-sha512@openssh.com,curve25519-sha256@libssh.org
- MACs: hmac-sha2-256-etm@openssh.com,hmac-sha2-512-etm@openssh.com,umac-128-etm@openssh.com
- Encryption ciphers: Ciphers aes128-ctr,aes192-ctr,aes256-ctr,aes128-gcm@openssh.com,aes256-gcm@openssh.com,chacha20-poly1305@openssh.com
Prior to upgrading, we recommend that you:
- Update your SSH client to the latest version.
- Confirm your client supports the above configurations.
- Take a backup (snapshot) of your virtual machine.
- Upgrade a single machine first to confirm connectivity and then proceed to the others.
Files
This file... |
Should be applied on top of... |
---|---|
gw-TAG_GW_24_2_1_23-bundle.vidyo |
VidyoReplay version 22.2.2 or later |
Upgrade notes
- You must upgrade to VidyoGateway version 24.2.1 from VidyoGateway version 21.1.x or later. Therefore, if you have a VidyoGateway version earlier than 21.1.x, you must first upgrade to 21.1.x and then upgrade to version 24.2.1. Please refer to the “Upgrade a VidyoGateway 21.1.x Cluster to Version 24.2.1” section below for more information. These steps must be completed in order.
- If you have installed a previous VidyoGateway version 24.2.1 beta, you should first downgrade your VidyoGateway to the previous GA using the Recovery Utility on the System Console, and then upgrade directly to the GA 24.2.1 version. For more information, please refer to Run the Recovery Utility section of the VidyoGateway Administrator Guide.
Compatibility
VidyoGateway version 24.2.1 is compatible with VidyoPortal and VidyoRouter versions 24.1.0 and later.
Resolved issues
The following table lists the issues we have resolved in VidyoReplay version 24.2.1.
VidyoReplay version 24.2.1 - resolved issues |
|
---|---|
Key |
Summary |
VIDGW-5147 |
Fixed an issue where under certain rare circumstances, all cluster nodes may simultaneously display as "Offline" and no calls will connect. |
VIDGW-5114 |
Fixed an issue where pushing of statistics to VidyoInsights of VidyoGateway participants do not show up correctly. |
Known issues
There are no new known issues for this release.